Odrid HMI

Odrid HMI

Industrial grade HMI/SCADA

$24.99
Click to generate a QR code for easy access to the app on the App Store

Details about Odrid HMI

  • Released
  • Updated
  • iOS Version
  • Age Rating
  • Size
  • Devices
  • Languages

Developer of Odrid HMI

Odrid HMI screenshot #1 for iPhone
iphone
ipad
🙌3
Ratings
🗣❌ unsupported
Your locale
🖼️Download
Icons↘︎

Version History of Odrid HMI

1.7.9

February 27, 2024

1.7.9: Bug fixes/improvements in the protocol drivers for Modbus and Siemens S7 Communication (ISO-on-TCP). 1.7.8: Error messages for different Siemens S7 String issues. Bug fix for system register 65452 (last Siemens S7 polled DBNO). Bug fix for lighted push button with a non zero register offset. The term 'Panel' is changed to 'Page'.

More

1.7.7

December 19, 2023

Version 1.7.7 Bug fixes for the Register offset feature In the Modbus protocol drivers. Version 1.7.6 New feature in the settings "Disconnect on rx timeout" for Modbus RTU. New system registers for Modbus RTU for enable and online per Device ID. Bug fixes.

More

1.7.5

August 1, 2023

Bug fix for transparency in image buttons not working correctly.

1.7.4

May 23, 2023

1.7.4 Support for Vietnamese character set. 1.7.3 Bug fix for writing strings with reversed byte order using Modbus. The Slider object is disabled if the connected variable does not have a valid value. Improvement for System register R64542 (S7 DBNO) when using the Siemens S7 Communication (ISO-on-TCP) protocol. Minor changes in the Button and Input field objects.

More

1.7.2

December 27, 2022

On the first page, the Home button in the Navigation bar is disabled instead of hidden to overcome the problem that the Home and Menu buttons were not aligned vertically on some devices. Bug fix for missing default value of 1 second for the sampling interval in the logging mode in the Line Graph object. Improvements for parsing the directives in the comment section for controlling the logging mode in the Line Graph object.

More

1.7.1

November 29, 2022

Bug fix for reading variables of type Coil and Discrete Input with address 0 in the protocol drivers for Modbus/TCP Class 1 and Modbus RTU Class 1. A message that tells the user why the app is requesting access to the local network.

More

1.7.0

November 1, 2022

New option "Always read full bytes" for Modbus. Support for Korean character set. Bug fixes.

More

1.6.10

August 9, 2022

1.6.10: Bug fix for input in the As Text format. 1.6.9: When importing content, a warning is displayed before any files are overwritten. The change value dialog displays the name of the text list when using the As Text format. The Numeric variable object supports input in the As Text format. Support for Baltic character set. Support for Arabic character set. Bug fix for crash if panel (page) contains an image object without a filename. Bug fix for incorrect positioning of image objects during certain circumstances.

More

1.6.5

May 3, 2022

Bug fix for manipulating boolean variables mapped on bits in Modbus Holding registers.

1.6.4

April 26, 2022

Bug fix for reading 32-bit integer and floating point variables in the Modbus protocol drivers. (1.6.4) Bug fix for writing 32-bit integers in the Siemens S7 Communication (ISO-on-TCP) protocol driver. (1.6.3) Support for Hebrew character set. (1.6.2)

More

Price History of Odrid HMI

Description of Odrid HMI

Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP). Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between pages using swipe gestures or buttons. Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home. Advantages: Excellent technical support. Free updates. Graphic HMIs with multi touch function can be created in minutes. Free-of-charge development tool with test run feature. Virtually unlimited number of pages, objects and variables. Does not require any third-party services. Genuine native app. Features: Parameters for communication such as IP address, port number, protocol, etc. can be specified per page. Automatic polling of all variables displayed in the current page, no need for separate tag list. Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc. Prioritized event-driven transfer to the controller. Pages are edited in the measurement unit dp (Density Independent Pixels). Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.) Numeric variables can be displayed as predefined text for example alarms, sequence steps etc. Detailed diagnostics of connection and communication. Variable areas for system variables, local variables and constants. Possibility of automatic return to the start page after some time of inactivity. Selectable order for high and low words of 32-bit variables in the Modbus protocol. Poll interval can be set do save data traffic or battery. Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish, Vietnamese and Western character sets. Ability to test run pages in the development tool. LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems. Background color for pages can be selected. Modbus Device ID can be changed with GUI objects during operation. Image buttons. Password fields. Floating point and hexadecimal number formatting. Timestamp for page files. Hyperlinks. Document information in page files. Implemented protocols in the current version: Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers. Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils). Modbus RTU: Class 0 and 1. Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas. (Default value for highest Siemens S7 databock is 255.) Free-of-charge development tool for creating the pages to be used by Odrid HMI: https://www.idea-teknik.com/odrid_hmi_download.html Manual: https://www.idea-teknik.com/odrid_hmi_manual.html Version history: https://www.idea-teknik.com/odrid_hmi_version_history.html Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc. S7 and STEP 7 are trademarks of Siemens AG.
Show less

Odrid HMI: FAQ

Is Odrid HMI compatible with the iPad?

Yes, there is an iPad version available for Odrid HMI.

Who launched the app?

Jan Almqvist is the developer of Odrid HMI.

What’s the minimum iOS version needed for the Odrid HMI app?

The minimum iOS requirement for the app is 12.0 or higher.

How do users rate the Odrid HMI app?

5 out of 5 is the fantastic rating that Odrid HMI has received from users.

What genre is the Odrid HMI app?

The App Category Of Odrid Hmi Is Productivity.

What’s the current version of the Odrid HMI app?

The current version of Odrid HMI is 1.7.9.

When was the most recent Odrid HMI update made available?

Odrid HMI updated on December 1, 2024.

Do you know when Odrid HMI was first made available?

The specific date when the app came out was February 6, 2023.

What content advisory rating is assigned to Odrid HMI?

No objectionable content, suitable for young children.

What are the languages supported by the Odrid HMI app?

Currently, Odrid HMI supports English.

Is Odrid HMI included in the roster of games on Apple Arcade?

No, Odrid HMI is not on Apple Arcade.

Does Odrid HMI support in-app purchases?

No, Odrid HMI does not support in-app purchases.

Is Odrid HMI designed for Apple Vision Pro integration?

Sorry, Odrid HMI is not designed for integration with Apple Vision Pro.

Does Odrid HMI use ad-based monetization?

No, Odrid HMI does not use ad-based monetization.

Alternatives to Odrid HMI

Reviews of Odrid HMI

Great Support

Great value awesome and timely support.

Click with Modbus TCP. Very pleased.

Works great! Quickly set up a screen to change the start times of my 4 zone sprinkler system. PLC is a Automation Direct Click with Modbus TCP. Addressing was a little tricky but used the application example and had it working in about an hour. Very pleased.

HMI for iOS

This is a very simple and highly effective HMI for iOS. I looked for years for something simple, quick to setup, and cost effective. So far, this is the best. Very reliable communications drivers. For the price, there is enough functionality. The support is immediate and accommodating. I needed an enhancement done to the scaling routine and it was ready and released in a couple of weeks. I am using this app to allow operators and maintenance people to remotely read a critical water tank level and backup power IO for a small town public water system.
Show less