Box Fill Calc NEC

Box Fill Calc NEC

NEC Art.314 Box Volume

0 ratings
With Ads#200 in paid Utilities
🔧 Utilities
💼 Business
$0.99
In-App PurchasesWith Ads

Rating summary

Details

  • Released
  • Updated
  • April 24, 2026
  • June 10, 2026

Features

Box Fill Calc NEC screenshot #1 for iPhone
Box Fill Calc NEC screenshot #2 for iPhone
Box Fill Calc NEC screenshot #3 for iPhone
Box Fill Calc NEC screenshot #4 for iPhone
iphone
ipad
🖼️Get Icon
Icons↘︎

About

NEC box fill calculator for electricians, apprentices, and electrical engineers. Calculate box fill volumes instantly using official NEC 2023 Article 314.16 data (Tables 314.16(A) and 314.16(B)). No internet required - works 100% offline on the job site. FEATURES: - All 24 standard metal box sizes from Table 314.16(A): Device 3x2 and 4x2-1/8 (handy box), Round/Octagonal, Square 4", Square 4-11/16", Masonry, FS, FD - Custom volume entry for non-standard boxes - Conductor sizes: 18 AWG to 6 AWG per Table 314.16(B) - Internal cable clamps, fixture studs, and hickeys - Multi-gang device fill calculation - Equipment grounding conductors (EGC) with NEC 2023 rules - Isolated grounding conductors - separate allowance - Visual PASS/FAIL indicator with fill percentage - Shows minimum box volume needed when over-filled - Suggests a standard box that will pass PRO FEATURES (one-time purchase): - No ads - Save calculation history - Export calculations as PDF reports - Dark theme support BUILT FOR THE JOB SITE: This app is designed by electricians, for electricians. The interface is clean, fast, and works with one hand. Add conductors, check your fill, and move on - no complicated menus or unnecessary features. ACCURATE NEC DATA: All box volumes are sourced from NEC 2023 Table 314.16(A). Conductor volume allowances follow Table 314.16(B) exactly. Fill rules follow Article 314.16 for conductors, clamps, support fittings, devices, and grounding conductors. Always verify calculations against the official NEC code book before installation. NEC 314.16 FILL RULES: - Each conductor: volume from Table 314.16(B) based on AWG size - Internal clamps: 1× largest conductor volume (all clamps combined) - Support fittings: 1× largest conductor per fitting type - Devices: 2× largest conductor per gang - EGC (≤4): 1× largest EGC volume - EGC (>4, NEC 2023): 1/4 allowance per additional conductor - Isolated grounds: counted separately PERFECT FOR: - Licensed electricians - Electrical apprentices - Electrical engineers and designers - Electrical contractors - DIY electrical projects - NEC code exam preparation (Journeyman & Master) OFFLINE & PRIVACY: - Works 100% offline - no internet needed - No account required - No data collection - Your calculations stay on your device Simplify your box fill calculations on the job site.
Show more

What's New in Box Fill Calc NEC

1.0.9

June 10, 2026

What's new: • Complete NEC Table 314.16(A) catalog — added 4x2-1/8 device boxes (handy box): 10.3, 13.0, 14.5 cu.in. All 24 standard metal box sizes covered • Fixed EGC fill per NEC 2023 314.16(B)(5): each EGC beyond 4 now adds a 1/4 volume allowance Thanks for using ElecTools! Send feedback to support@tradetools.dev.

More
1

In-App Purchases

$2.99

Pro Unlock

No ads, unlimited history, PDF export, dark theme.