Chronolyze: Watch Accuracy

Chronolyze: Watch Accuracy

Mechanical Watch Diagnostics

0 ratings
Free

Rating summary

Details

  • Released
  • Updated
  • July 24, 2026
  • August 31, 2026

Features

Chronolyze: Watch Accuracy screenshot #1 for iPhone
Chronolyze: Watch Accuracy screenshot #2 for iPhone
Chronolyze: Watch Accuracy screenshot #3 for iPhone
Chronolyze: Watch Accuracy screenshot #4 for iPhone
Chronolyze: Watch Accuracy screenshot #5 for iPhone
iphone
ipad
🖼️Get Icon
Icons↘︎

About

Chronolyze turns your iPhone into a precision timegrapher for mechanical watches. Rest your watch against the microphone and watch the classic paper-tape trace draw itself — no bench equipment, no clip-on sensors. Every mechanical watch tells you how healthy it is through its ticking. Chronolyze listens to the escapement's impulses and measures the timing between them with sub-millisecond precision. LIVE MEASUREMENT • Rate in seconds per day — is your watch running fast or slow? • Beat error in milliseconds — is the balance swinging symmetrically? • Amplitude in degrees — how much power reaches the balance wheel? • Stability — how steady the rate is holding, so you can tell a settled movement from a restless one • Automatic beat-rate detection from 12,000 to 36,000 bph • Classic two-line timegrapher trace: slope shows rate, gap shows beat error • Signal-quality meter so you know when to trust the numbers • A plain-language verdict on every finished measurement, and a report card you can share ACCURACY TRACKING The bench tells you how a watch behaves in thirty seconds. This tells you how it behaves on your wrist. Tap along with the seconds hand every few days and Chronolyze works out how many seconds a day your watch really gains or loses in daily wear — then compare that with the timegrapher reading. A watch that's +2 s/day on the desk but −12 on the wrist has a positional problem, not a rate problem. No microphone needed, so it works even for watches too quiet to measure. POSITIONAL TEST Measure in the six regulation positions — dial up, dial down, crown up, down, left, right — with a guided workflow. The positional variation (Δ) is the number a watchmaker regulates against: Chronolyze computes it and tells you what it means. MAGNETIZATION CHECK A suddenly fast watch is usually a magnetized hairspring. Chronolyze uses your iPhone's magnetometer to detect it in seconds, before you pay for a service you don't need. WATCH COLLECTION Keep a watch box in your pocket: per-watch lift angle and beat rate, full measurement history, saved positional runs, accuracy readings, and re-viewable traces for every session. Everything syncs through your own iCloud account, so your collection follows you to every device. BUILT FOR WATCH PEOPLE • A library of 104 movements — Seiko, ETA, Sellita, Miyota, Rolex, Omega, Longines, Citizen, Hamilton, Grand Seiko, Tudor and more — each with the right lift angle and beat rate already set • Set the lift angle by hand for anything not listed (default 52°) • Pin a nominal beat rate for unusual movements • Dark, instrument-grade interface with iOS 26 Liquid Glass design • Demo movement mode so you can explore every feature without a watch • An animated escapement in Settings that shows exactly what you're hearing WHAT YOU NEED A quiet room and a mechanical watch (hand-wound or automatic). Quartz watches don't tick the same way and aren't supported — Chronolyze recognises one and says so rather than reporting nonsense. For best results, rest the watch case directly against the bottom edge of the phone. Whether you're regulating your own movements, checking a vintage find before you buy, or just curious how your daily wearer is doing — Chronolyze gives you watchmaker-grade numbers from the phone already in your pocket.
Show more

What's New in Chronolyze

1.3.1

August 31, 2026

Two checks that could confidently give the wrong answer are fixed, and the graph has room to breathe. • Magnetization now measures the watch, not the phone. Turning the phone could report "Magnetized" with no watch present — it now uses a corrected field, and gives no verdict at all if the phone moved while it ran • A watch with the wrong beat rate set no longer gives a confident wrong reading. Chronolyze checks what it hears against what it was told, and says when the two disagree • More room for the graph on the Measure screen: the readings are one compact panel, and the trace is more than twice as tall • On iPad the bottom of the Measure screen is no longer out of reach, and Diagnose is a list again rather than a row across the top • Measurements are no longer lost when the watch they were taken for has been deleted • "How a Tick Works" has moved from Settings into How To, and the escapement animation is redrawn • Also fixed: a quiet watch mislabelled as quartz, the positional test not saying when it couldn't hear anything, two measurements starting at once, and the report card naming a renamed watch

More

Developer apps