Heat Loss Planner

Heat Loss Planner

Heat Load & Radiator Sizing

0 ratings
Free
In-App Purchases

Rating summary

Details

Released
November 10, 2026
Updated
November 10, 2026

Features

Heat Loss Planner screenshot #1 for iPhone
Heat Loss Planner screenshot #2 for iPhone
Heat Loss Planner screenshot #3 for iPhone
Heat Loss Planner screenshot #4 for iPhone
Heat Loss Planner screenshot #5 for iPhone
🖼️Get Icon
Icons↘︎

About

Heat Loss Planner calculates the heat load of every room following EN 12831 and sizes radiators for the flow temperature you actually run — on site, on your iPhone. ROOM BY ROOM Add rooms with their walls, windows, doors, floor and roof. Pick U-values from the library (GEG reference values, DBN minimums, typical older constructions) or enter your own. Set what lies beyond each element: outside air, an unheated space, the ground or a heated neighbour. CLIMATE FOR YOUR TOWN Search for your town or use your location. The design outdoor temperature is estimated following EN 12831 from 20 years of PVGIS data (European Commission); the annual mean is used for heat loss to the ground. You can always enter the value from your national standard. WHAT IT CALCULATES • Transmission and ventilation heat loss of each room and of the whole building, in W and BTU/h • Thermal bridges as a ΔU surcharge, infiltration from a blower door n50, heat recovery • Radiator output converted from 75/65/20 to your flow and return temperatures (EN 442) • The shortest steel panel radiator of type 11, 21, 22 or 33 that covers each room • Whether the existing radiators are enough, room by room PRO — ONE-TIME PURCHASE, NO SUBSCRIPTION • Unlimited projects and rooms (free: one project, three rooms) • Lowest flow temperature for the existing radiators — is the house ready for a heat pump? • U-value from layers (EN ISO 6946) • Your own radiators from the datasheet, sectional radiators rated at ΔT70 • PDF report for your client: rooms, elements and radiators No account. Your projects stay on your device.Heat Loss Planner calculates the heat load of every room following EN 12831 and sizes radiators for the flow temperature you actually run — on site, on your iPhone. ROOM BY ROOM Add rooms with their walls, windows, doors, floor and roof. Pick U-values from the library (GEG reference values, DBN minimums, typical older constructions) or enter your own. Set what lies beyond each element: outside air, an unheated space, the ground or a heated neighbour. CLIMATE FOR YOUR TOWN Search for your town or use your location. The design outdoor temperature is estimated following EN 12831 from 20 years of PVGIS data (European Commission); the annual mean is used for heat loss to the ground. You can always enter the value from your national standard. WHAT IT CALCULATES • Transmission and ventilation heat loss of each room and of the whole building, in W and BTU/h • Thermal bridges as a ΔU surcharge, infiltration from a blower door n50, heat recovery • Radiator output converted from 75/65/20 to your flow and return temperatures (EN 442) • The shortest steel panel radiator of type 11, 21, 22 or 33 that covers each room • Whether the existing radiators are enough, room by room PRO — ONE-TIME PURCHASE, NO SUBSCRIPTION • Unlimited projects and rooms (free: one project, three rooms) • Lowest flow temperature for the existing radiators — is the house ready for a heat pump? • U-value from layers (EN ISO 6946) • Your own radiators from the datasheet, sectional radiators rated at ΔT70 • PDF report for your client: rooms, elements and radiators No account. Your projects stay on your device. Results are an engineering estimate for sizing equipment. Check U-values and design temperatures against your national standards. Results are an engineering estimate for sizing equipment. Check U-values and design temperatures against your national standards.
Show more

What's New in Heat Loss Planner

1.0

November 10, 2026

1

Subscriptions & In-App Purchases

$14.99

Heat Loss Planner Pro

Unlimited projects, lowest flow, U from layers, PDF