Plant Calculator

Plant Calculator

Plant inspection & operations

0 ratings
Free
Ad data

Rating summary

Details

Released
June 22, 2026
Updated
November 21, 2026

Features

Plant Calculator screenshot #1 for iPhone
Plant Calculator screenshot #2 for iPhone
Plant Calculator screenshot #3 for iPhone
Plant Calculator screenshot #4 for iPhone
Plant Calculator screenshot #5 for iPhone
Plant Calculator screenshot #6 for iPhone
Plant Calculator screenshot #7 for iPhone
Plant Calculator screenshot #8 for iPhone
Plant Calculator screenshot #9 for iPhone
Plant Calculator screenshot #10 for iPhone
iphone
ipad
🖼️Get Icon
Icons↘︎

About

The nameplate reads "52.7 kg/cm²G." Your reference is in psi. The formula wants MPa. You can stop doing that conversion in your head. Plant Calculator brings together the calculations used every day in refinery and chemical plants — inspection on piping and vessels, operations on flow, heat and fluid properties. ■ Type the number on the nameplate, as-is Every input field has a unit selector. Enter kg/cm²G, psi or bar exactly as written and the app converts; set your usual unit as the default. 15 categories, 69 units. ■ Type the board reading, as-is Pressure inputs on the operations screens have a gauge/absolute toggle. Field instruments read gauge; property calculations need absolute — the app handles the difference. ■ Works where there's no signal Inside a vessel or a tank — every calculation runs on your device. ■ Keep what you use at the top Tap the star on a tile and it moves to the top; groups fold away when you don't need them. How the star responds is yours to set. ■ Enter only what you already know - Pick a nominal size and schedule; OD and wall are filled in (ASME/JIS) - Pick a material and temperature; the allowable stress is interpolated - Tap "?" on any field for what the value is and where to find it (264 entries) ■ Inspection & strength - Quick Check: original wall, required thickness, corrosion rate, remaining life and margin - Required thickness for piping and pressure vessels under internal pressure (JIS B 8265 / KHK, ASME Sec.VIII Div.1, B31.3; cylinders, heads, straight pipe, elbows) - Corrosion rate and remaining life from previous/current thickness - Metal loss check: average, minimum and variation, general and local - Vertical tower: pressure, dead weight, wind and seismic (static coefficient method), operating and shutdown, skirt - External pressure, nozzle reinforcement, relief valve sizing (API 520 based) - Piping span, pressure drop, velocity; flange, bolt torque, flat plate, cone, support loads - Surface area of pipe, elbow, head, reducer, for painting and cladding - Tank / line totals, thermal expansion - Bolt torque, carbon equivalent, Larson-Miller, hydrotest pressure, relief backpressure, PWHT/preheat check ■ Operations & process - Steam table: saturation temperature, enthalpy, latent heat; superheated and flash steam - Flow-meter P/T correction for differential-pressure meters - Orifice meter: differential pressure ↔ flow, and the bore for a target flow - Gas flow conversion: Nm³/h ↔ actual m³/h ↔ kg/h - API gravity & density; gas concentration (ppm ↔ mg/Nm³, O₂ correction, %LEL) - Heat exchanger: duty, LMTD, U value, fouling, tube plugging - Insulation: heat loss and outer surface temperature, pipe and flat - Pump: NPSHa, hydraulic and shaft power, affinity laws - Compressor: power, discharge temperature and ratio (adiabatic or polytropic) - Pipe pressure drop; control valve Cv; motor load from an ammeter - Instrument scaling (4-20 mA ↔ % ↔ engineering units, square root) - Combustion: flue gas O₂ ↔ excess air, heating value, theoretical air - Viscosity: cSt ↔ SSU ↔ mPa·s, two-point temperature interpolation, blending ■ Tools & reference - Scientific calculator with an equation solver for x, y and z - Unit conversion: 15 categories, with unit-aware multiplication and division (e.g. 200 mm × 200 mm = 0.04 m²) - Size quick reference and pipe dimension lookup (ASME B36.10M/B36.19M, JIS) - Flange rating check: your standard's rated pressure vs. the design pressure (table not bundled) - Materials: allowable stress by temperature; 47-grade property catalog - Glossary: 264 field explanations, searchable and filterable - Calculation history; 8 languages; dark mode ■ Important This app is a supporting tool. Formulas are representative; allowable stresses, dimensions, ratings and properties are approximate reference values. Always verify against the applicable codes, vendor datasheets or your company standards before deciding. Do not rely on this app's results alone.
Show more
+1

What's New in Plant Calculator

1.7.0

November 21, 2026

■ Seven maintenance calculations (48 in all) - Bolt tightening: stress area, bolt load, torque and gasket stress from the thread size. Metric coarse and inch (UNC, 8UN) - Carbon equivalent: Ceq (IIW, JIS/WES) and Pcm from the mill certificate - Larson-Miller: metal temperature vs. time in the creep range — how much faster a heater tube uses its life when it runs 10 °C hotter - HX tube plugging: plug ratio, and the allowable ratio and tubes left from the design margins (area, velocity, pressure drop) - Hydrotest pressure with temperature correction, liquid head and shell stress - Relief valve backpressure as a share of set pressure, with CDTP - PWHT and preheat: procedure limits checked against the records - Piping erosion velocity: a two-phase helper turns gas and liquid flows into mixture density and velocity ■ Material catalog (a new tab in Materials) 47 grades — copper alloys (C1220, admiralty brass, copper-nickel), Cr-Mo, low-temperature steels, stainless, duplex, nickel alloys, titanium, aluminium — with specified minimum strength, density, modulus, expansion, conductivity and typical use. Search by grade or name ■ Your own material values Override catalog values from your standard or mill certificate, or add a grade. Enter an allowable stress table and it becomes selectable in required thickness, vertical tower and quick check. Stored on this device only ■ Three operations calculations - Compressor: power, discharge temperature and ratio (adiabatic or polytropic) - Orifice meter: flow from differential pressure, the reverse, or the bore for a target flow - Insulation: heat loss and outer surface temperature, including whether it is safe to touch ■ Easier to read Result numbers are bolder and units quieter. Digits are fixed-width, so values no longer shift as you type, and long numbers are grouped (2 365 000). Support span now shows the weight breakdown with insulation and the hydrotest weight ■ Pin what you use to the top Tap the star on a tile; choose how the star responds in Settings. Groups in the menu fold with the triangle on the heading ■ Fixes - The calculator shows the answer from the start ("1 ÷ 3" hid the leading "0.") - Gauge pressure fields accept negative values for vacuum service

More

Developer apps