Comparison

Isoelectric Point vs Uncertainty Calculator

Price, ratings, monetisation and update history for both apps, side by side — with what reviewers say about each.

Head to head
About

Isoelectric Point

Features
Read full description

Isoelectric Point (IEP) helps to estimate the charge of macromolecule (proteins, peptides, amino acids, DNA, etc.), consisting of basic and acidic residues as a function of pH value of solution. The application graphically represents the charge fluctuation over the whole range of pH values and finds out the isoelectric point value. The application can extract the protein sequence (chain by chain) from FASTA files. Layout of "IEP".  The sequence of polymer molecule can be typed into the “Sequence” field in the single letter format (YHRK…). Alternatively, it can be uploaded from the PDB-styled FASTA file (for polypeptides) located in "Documents/IEP" folder. Pressing “Load” bar button launches file browser that lets the user to choose the FASTA file. Simple press on 'Chain' button launches chain picker dialog if multiple chains are defined in FASTA file. If peptide is analysed, then tapping “Analyse” button, calculates the molar weight, counts and fills in the number of recognized acidic and basic residues into the appropriate cells in the amino acid info table. Cells for acidic residues are coloured red and for basic are blue. Each row provides three cells: 1. compound (amino acid) name or acronym. 2. pKa value (user defined), default values are provided. 3. Number of the particular residues in the macromolecule. The “-C” and “-N” cells represent standard C- and N-terminus respectively. If peptide has been terminally modified, then these fields data must be changed accordingly. The “Calculate” button initiates the analysis of the table data and outputs the IEP value. Important! Table data can be fully customized after or without any sequence analysis! IEP calculation uses table values, whatever their origin is . Long press on 'Reset' button removes amino acid data from table if the analysed molecule is not based on amino acid sequence or alternatively brings it back if peptide is analysed. Short Tap on reset button simply resets data in table. Application provides data for most common acidic and basic amino acid residues, but every cell can be updated! Sequence analysis reverts the table back to its original state. Important points: Special attention should be paid for number of -C and -N termini and their pKa values, as they depend on functional derivaterization and number of chains being analysed. If user updates any of the data cells, the program will not start to plot until user press calculate button and only if the update is accepted. The cells are colored according to the data input allowed (unchangeable): red for acidic and blue for basic function. However both acidic and basic residue chemical groups are usually provided with pKa values. In case that pKb value is provided, it can be easily converted to pKa using: pKa=pKw-pKb or pKa=14-pKb (at 25°C). User should check what the primary chemical property of the residue is: the proton donor, gaining negative charge (acidic) or proton acceptor, gaining positive charge (basic). Unrecognized amino acid residue letters are skipped, but can be added manually to the available cells. The empty cell sets are available for custom input. The pKa values can be changed in table to fit the desired model. The application assumes no influence between residues. The application assigns dot as a decimal separator.

About

Uncertainty Calculator

This app allows users to perform error propagation calculations for mathematical expressions involving uncertain variables. It supports absolute and relative error inputs, various functions, and trigonometric calculations in degrees or radians. The tool helps ensure accurate reporting of results based on estimated errors.

Highlights
  • Error propagation calculations
  • Absolute and relative error input
  • Support for mathematical functions
  • Trigonometric calculations (degrees/radians)
  • Variable combination in expressions
  • Significant figure guidance
Features
Read full description

Uncertainty Calculator evaluates the error propagation throughout the mathematical expressions comprised of variables of uncertain value. The application allows input of up to three value-error pairs (A, B and C), that can be used as a parameters in the final expression. Error values should be provided in absolute (100 +/- 5) or in relative format, the latter should appear in percent format (100 +/- 5%). The evaluated expression can include numerous functions, that provided by row of the appropriate buttons. Components and functions can be added directly to the expression field by pressing the corresponding buttons. To encompass expression into the preset formula, select the expression and press the corresponding formula button. Particular attention should be paid to placing brackets to avoid equation ambiguity. The application deals with independent, random errors. So if this is a case never use A + A, but rather 2*A and never A*A*A but rather A^3! Obviously, different parameters can be combined in any way (A+B or C *A^2 .. is perfectly fine). Angles for trigonometric functions can be provided in degrees or radians, and that should be reflected by setting a yellow button to "DEG" or "RAD". Bear in mind the importance of units in any of calculations! Implementation Examples: 1.The charge passing through an electrical circuit is defined by: Q = I * t, where I is the current and t is the time. Calculate the total charge value when a current of 0.15 ± 0.01 A passes through the circuit for 120 ± 1 s: Input: A = 0.15 ± 0.01, B = 120 ± 1 The final expression will be A*B, and press Calculate: The final value will be: 18 ± 1.2 Thus, it can be reported the total charge as 18 C ± 1 C. Important! One should only report as many significant figures as are consistent with estimated error! So the value should be rounded to the rightmost decimal place at which error applies. 2. A ball is tossed straight up into the air with initial speed vo = (4.0± 0.2) m/s. After a time t = (0.60 ± 10%) s, the height of the ball is h = vo*t - 0.5gt^2 = 0.636 m (g = 9.80 m/s^2). What is the value and uncertainty of height? Input: A = vo = 4.0 ± 0.2, and B = t = 0.60 ± 10%, then the final expression should be: A*B – 0.5*9.8*B^2 The final value will be: 0.6 ± 0.4 (meters).

Screenshots

Isoelectric Point4 screens
Uncertainty Calculator4 screens

Verdict

The call

The clearest difference is price: Isoelectric Point at $2.99 against Uncertainty Calculator's $3.99. Isoelectric Point also leads on iOS requirement (15.3 vs 17.0). On update cadence, ads, in-app purchases and device support there is nothing between them.

Scored on Price · Rating · Positive reviews · Number of ratings · Update frequency · Ads · In-app purchases · Monetization · Best chart rank · Devices · Requires iOS

CostPrice · In-app purchases · Ads · Monetization

Isoelectric Point costs $2.99 and Uncertainty Calculator $3.99 up front. Neither carries in-app purchases, so what you see is what you pay.

UpkeepUpdate frequency

Isoelectric Point ships an update every 4 months, Uncertainty Calculator every 3 months. The most recent releases landed on November 1, 2026 and November 16, 2026 respectively.

Scorecard2 real differences · 7 level
Isoelectric Point versus Uncertainty Calculator: the parameters behind the verdict, then further details
ParameterIsoelectric PointUncertainty Calculator
Price$2.99 — better$3.99
Rating—5.0 (1 ratings) — better
Number of ratings—1 — better
Update frequencyEvery 4 monthsEvery 3 months — better
AdsNoNo
In-app purchasesNoNo
Monetization—Paid
DevicesiPhone, iPad, iPod — betteriPhone, iPad
Requires iOS15.3 — better17.0
Further details — not scored
Size3 MB1 MB
Age rating4+4+
DeveloperRoman VolinskyRoman Volinsky

In-app purchases

None

Isoelectric Point

No in-app purchases

None

Uncertainty Calculator

No in-app purchases

Questions

Is Isoelectric Point free?
Isoelectric Point costs $2.99, with no in-app purchases.
Is Uncertainty Calculator free?
Uncertainty Calculator costs $3.99, with no in-app purchases.
Do Isoelectric Point or Uncertainty Calculator have ads?
Neither Isoelectric Point nor Uncertainty Calculator shows ads.
Which is updated more often, Isoelectric Point or Uncertainty Calculator?
Isoelectric Point ships an update every 4 months, and Uncertainty Calculator every 3 months. Most recently, Isoelectric Point was updated on November 1, 2026 and Uncertainty Calculator on November 16, 2026.

Other comparisons