Modbus TCP FieldKit

Modbus TCP FieldKit

Client, Server, Simulator

0 ratings
$5.99

Rating summary

Details

Released
May 15, 2026
Updated
November 1, 2026

Features

Modbus TCP FieldKit screenshot #1 for iPhone
Modbus TCP FieldKit screenshot #2 for iPhone
Modbus TCP FieldKit screenshot #3 for iPhone
Modbus TCP FieldKit screenshot #4 for iPhone
Modbus TCP FieldKit screenshot #5 for iPhone
Modbus TCP FieldKit screenshot #6 for iPhone
Modbus TCP FieldKit screenshot #7 for iPhone
Modbus TCP FieldKit screenshot #8 for iPhone
iphone
ipad
🖼️Get Icon
Icons↘︎

About

Modbus TCP FieldKit puts a professional Modbus TCP toolkit in your pocket. Commission equipment in the field, validate setups in the lab, or troubleshoot home automation — all from your iPhone. • Connect to any Modbus TCP or RTU over TCP device — read coils and registers, monitor data blocks in real time • Modbus RTU over TCP — reach RS-485 devices through Wi-Fi or Ethernet converters in transparent mode (for example Elfin EW11, USR or Waveshare). If a read times out, the app offers to try the other framing with a single read. • Find devices and Scan Unit IDs on your own Wi-Fi subnet — ports 502, 1502, 8899 and 4196. Each device is read once and nothing is written. • Chart every monitored value — the app keeps the last 600 points or 1 hour per value while it is open — and Export CSV through the system share sheet. • Save device profiles for one-tap reconnection to frequently used endpoints • Write with confidence — every write operation requires your explicit confirmation • Built-in foreground simulator — run editable coils and holding registers for testing • Track active connections and review bounded local logs kept on your device • All data stays local — logs and diagnostic exports are sanitized by default Requires Local Network access for device communication. RS-485 devices connect through a Wi-Fi or Ethernet converter in transparent mode. Default server port is 1502. Background server operation and port 502 support pending device validation.
Show more

What's New in Modbus TCP FieldKit

1.2.2

November 1, 2026

New in 1.2.2: • When a device answers with a Modbus exception, you stay connected. Read, Write and Disconnect keep working on the same connection. • When a connection fails, the app names the cause it can tell: a closed port, a device name it cannot find, an address outside your network, or no Wi-Fi or Ethernet. • If the app cannot tell whether a write reached the device, the result says Write result unknown and asks you to read the value back before you write again. • Live monitoring over Modbus TCP keeps polling after one missed reply and stops after three in a row.

More

Developer apps