Thermochemistry vs Cloudlabs Control For Level
Price, ratings, monetisation and update history for both apps, side by side — with what reviewers say about each.
Thermochemistry
Read full descriptionHide full description
Thermochemistry helps in evaluation of enthalpy or heat release/absorption of a system undergoing numerous temperature changes and phase transitions. The calculations take advantage of known values of heat capacity at constant pressure (Cp) and molar or per gram enthalpy of phase transition. Amount of compound can be defined in grams or moles, in a way that Cp and enthalpy units would match. App provides enthalpy values for each step. Negative enthalpy points to exothermic process – heat release, while positive one to endothermic - heat absorption. °C and K are interchangeable. Calorimetry section provides means for evaluation of the heat capacity of calorimeter and for finding equilibrium temperature of mixed system. Forward arrow button sets the final temperature of the mixture. Backward arrow button sets missing temperature or heat capacity of one of the components. Enthalpy values show heat flow for each component. Example of problems solved by application (screenshots): Problem 1: Calculate the amount of energy required to change 100.0 g of ice at -15.0 °C to steam at 125.0 °C. Known values: Heat of melting = 334.16 J g¯1 Heat of vaporization = 2259 J g¯1 specific heat capacity for solid water (ice) = 2.06 J g¯1 K¯1 specific heat capacity for liquid water = 4.184 J g¯1 K¯1 specific heat capacity for gaseous water (steam) = 2.02 J g¯1K¯1 Solution: 1) Heating of 100.0 g of ice from -15.0°C to 0.0°C: (100.0 g) (15.0 K) (2.06 J g¯1 K¯1) = 3090 J 2) Melting of 100.0 g of ice: (100.0 g) (334.16 J g¯1) = 33416 J 3) Heating of 100.0 g of liquid water from zero to 100.0 Celsius: (100.0 g) (100.0 K) (4.184 J g¯1 K¯1) = 41840 J 4) Evaporations of 100.0 g of liquid: (100.0 g) (2259 J g¯1) = 225900 J 5) Heating of 100.0 g of steam from 100.0 to 125.0 Celsius: (100.0 g) (25.0 K) (2.02 J g¯1 K¯1) = 5050 J 6) Summation of the results: 3090 + 33416 + 41840 + 225900 + 5050 = 309.3 kJ Problem 2: Determine the heat capacity of a coffee-cup calorimeter. During calibration 100.0 g of water at 58.5 °C has been added to 100.0 g of water, already in the calorimeter, at 22.8 °C. Calculate the heat capacity of the calorimeter in J/°C, if final temperature of the water is 39.7 °C. (Specific heat of water is 4.184 J/g °C.) Solution: 1) Heat given up by warm water: q = (100.0 g) (18.8 °C) (4.184 J/g °C) = 7865.92 J 2) Heat absorbed by water in the calorimeter: q = (100.0 g) (16.9 °C) (4.184 J/g °C) = 7070.96 J 3) The difference was absorbed by the calorimeter: 7865.92 - 7070.96 = 794.96 J 4) Calorimeter constant: 794.96 J / 16.9 °C = 47.0 J/°C Problem 3: Determine the final temperature when 10.0 g of aluminum at 130.0 °C mixes with 200.0 grams of water at 25.0 °C. Please note the starting temperature of the metal is above the boiling point of water. In reality, the sample may vaporize a tiny amount of water, but we will assume it does not for the purposes of the calculation. Solution: 1) The colder water will warm up and the warmer metal will cool down. The whole mixture will equilibrate up at the same temperature. The energy which "flowed" out of the warmer metal equals the energy which "flowed" into the colder water: Qaluminum = Qwater (10) (130 - x) (0.901) = (200.0 )(x - 25) (4.18) 117.13 - 0.901x = 83.6x - 2090 x = 26.12 °C. Important! Water didn’t cross temperature of phase transition – vaporization; otherwise calculation would be more complex. Calculation of reaction standard Gibbs free energy: For the general reaction aA + bB -> cC + dD ΔG°rxn = cΔGf°(C) + dΔGf°(D) - aΔGf°(A) - bΔGf°(B) Example: Calculate the Gibbs free energy for the following reaction at 25 °C. Cu (s) + H2O (g) -> CuO (s) + H2 (g) ΔG°rxn = ΔGf°(CuO (s)) – ΔGf°(H2O (g)) = (–129.7 kJ/mol) – (–228.6 kJ/mol) = 98.9 kJ/mol ΔGf° = 0; for elements in their standard state by definition. At equilibrium, ΔG = 0! Important points Application uses dot as a decimal separator. Special attention should be paid for units’ consistency.
Cloudlabs Control For Level
Read full descriptionHide full description
In this laboratory practice we have a tank in which a control system can be implemented to maintain the tank level at a requested volume level of the tank to a requested volume. In this practice you can choose the type of control to be performed, PD (proportional derivative), PI (proportional integrative) or PID (Proportional Integral Derivative).
Screenshots
Verdict
The clearest difference is price: Cloudlabs Control For Level at Free against Thermochemistry's $3.99. Cloudlabs Control For Level also leads on iOS requirement (9.0 vs 17.0). On ads, in-app purchases and device support there is nothing between them.
Scored on Price · Rating · Positive reviews · Number of ratings · Update frequency · Ads · In-app purchases · Monetization · Best chart rank · Devices · Requires iOS
Cloudlabs Control For Level is free to download; Thermochemistry costs $3.99 up front. Neither carries in-app purchases, so what you see is what you pay.
| Parameter | Thermochemistry | Cloudlabs Control For Level |
|---|---|---|
| Price | $3.99 | Free — better |
| Update frequency | Every 4 months | — |
| Ads | No | No |
| In-app purchases | No | No |
| Devices | iPhone, iPad | iPhone, iPad, iPod — better |
| Requires iOS | 17.0 | 9.0 — better |
| Further details — not scored | ||
| Size | 1 MB | 86 MB |
| Age rating | 4+ | 17+ |
| Developer | Roman Volinsky | Jiovany Orozco |
In-app purchases
Thermochemistry
No in-app purchases
Cloudlabs Control For Level
No in-app purchases
Questions
Is Thermochemistry free?
Is Cloudlabs Control For Level free?
Do Thermochemistry or Cloudlabs Control For Level have ads?
Other comparisons















