This app facilitates EEG data recording and ERP analysis for research studies. It connects with specific EEG headsets to collect raw data and neurological study information. Recorded data can be exported for further analysis with various neuroscience tools.
What's New in PEER
4.2.2
September 25, 2026
4.2.2 Changes - PEER 4.2 introduced a regression where some recordings were shown as recorded at 500Hz when they were actually recorded at 250Hz. While PEER 4.2.1 corrected the underlying sample rate error, recordings made with PEER 4.2 displayed the incorrect 500Hz sample rate. PEER 4.2.2 corrects this error so that all recordings display their correct sample rate in the recording detail view. There is no impact on the underlying EEG data or marker placement. This fix also addresses related problems with exports (BrainVision and PEER Archive), ERP analyses, quality analysis, and EEG chart timebases. - Resolved a problem where PEER incorrectly recorded dropped samples when exiting the Signal Quality view. This view appears before each block of a game and in the Settings panel while an X.on is connected. PEER tracks lost samples using a counter the X.on sends with each block of data. Every time the Signal Quality view appears, PEER takes the headset in and out of impedance mode, and the headset restarts that counter. PEER was reading the restart as roughly 65,000 lost samples. This is why affected recordings reported dropped samples when in fact there was no lost data. For existing recordings made with PEER 4.2 and 4.2.1, you can ignore the displayed lost sample percentages. The EEG recorded during the trials is intact. In each affected recording, one of these events wrote many seconds of empty samples into the file, between two blocks rather than inside one. In a BrainVision export, this shows up as a stretch of zeros across all channels. Marker positions are unaffected, so epoching around the block markers works as it should. To find the gap, look for a long run of exact zeros between two block start markers. - BrainVision export now writes the correct sample rate for recordings made with PEER 4.2 that were incorrectly shown as 500Hz. Re-export any previously exported recordings to correct the sample rate. - The dropped samples percentage shown for a recording now excludes samples dropped during the Signal Quality view. - Improved the Signal Quality view to show ground and reference impedance. - Improved the Signal Quality view to prevent false displays of the “No reference signal” warning. - Resolved a problem where importing a PEER Archive set the recording’s build number to that of the version of PEER doing the import. Imported recordings now keep the build number of the version of PEER that made the recording. - The signal quality display in the Settings panel, shown while connected to an X.on, now matches the Signal Quality view, including ground and reference impedance. - The Bluetooth UUID is no longer shown in the EEG headbands list. - Addressed a problem where the Select All/None, Share and Delete bottom toolbar buttons are missing when the Recordings View is in edit mode. This problem arises on iOS 26 and later. PEER 4.2.1 Changes - Resolved a problem where null EEG data was recorded during baseline recordings. - Resolved a problem where X.on game recordings contained 250Hz data despite the application indicating the recordings contained 500Hz data. This problem did not affect raw EEG recordings. The problem occurred when PEER’s Signal Quality view placed the X.on in Impedance mode, where the X.on switches to a 250Hz sample rate. When the Signal Quality view was dismissed, PEER returned the device to EEG mode but failed to switch it back to 500Hz. - Improved impedance displays in the Signal Quality view. - Improved detail view appearance under iOS Liquid Glass (iOS 26 and later). - Internal code cleanup.
MoreSubscriptions & In-App Purchases
$499.99
Gambling Task/Doors
Record Gambling Task/Doors ERP studies
User reviews
FAQ
What is PEER used for?
PEER is designed for EEG recording and ERP analysis specifically for research studies. It collects raw EEG data and data related to neurological studies, allowing researchers to export it for further analysis.
Does PEER require specific hardware?
Yes, PEER communicates with Brain Products X.on EEG headsets. It is designed to work with this specific hardware for data collection.
Can PEER data be used with other analysis tools?
Yes, the recorded EEG data can be exported in formats compatible with MATLAB, BrainVision Analyzer, and other tools commonly used by neuroscience researchers.
What types of neurological studies does PEER support?
PEER supports studies involving Event-Related Potentials (ERPs), including passive and response-based Visual Oddball and Audio Oddball tasks. It also includes games like N-Back and Gambling Task.
Is PEER a medical device?
No, PEER is explicitly stated to be for research use only and is not a diagnostic or medical device.
What devices does PEER support?
PEER is supported on iPhone, iPad, and iPod devices, indicating broad compatibility within the Apple ecosystem.
How often is PEER updated?
The latest version of PEER is 4.2, and it was last updated on January 28, 2026. This suggests a proactive development cycle for the application.
Does PEER have ads?
No, PEER does not contain advertisements. The app is free to use and does not display any in-app ads.